Albumin 100

Albumin 100

Product Details:

  • Appearance Biochemistry reagent
  • Taste Other
  • Physical Form Other
  • Shelf Life 18 Months
  • Smell Other
  • Other Names Biochemistry reagent
  • Usage Auto Zyme Albumin can be used on any Spectrophotometer, Discrete semiautomated and Automated analyzer. Programme can be designed for any specific analyzer upon request.
  • Supply Ability : 10000 Kit Per Day
536 INR/Kit
X

Price And Quantity

  • 536 INR/Kit
  • 1 Kit

Product Specifications

  • Biochemistry reagent
  • Other
  • Other
  • 18 Months
  • ACC554326
  • Other
  • 100
  • Biochemistry reagent
  • Auto Zyme Albumin can be used on any Spectrophotometer, Discrete semiautomated and Automated analyzer. Programme can be designed for any specific analyzer upon request.
  • Biochemistry reagent
  • Other
  • Reagents
  • other

Trade Information

  • EXW ABPL
  • Paypal, Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Letter of Credit (L/C), Letter of Credit at Sight (Sight L/C)
  • 10000 Kit Per Day
  • 2 Days
  • Yes
  • packaging : Empity
  • Asia, Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa
  • All India
  • certification : iso

Product Description

Introduction

  • Auto Zyme Albumin is a reagent set for determination of Albumin in serum or plasma based on BCG method.
  • Auto Zyme Albumin is a single reagent system, ready-to-use.
  • Auto Zyme Albumin is a linear upto 6 gm%.
  • Albumin can be determined in just 1 minute at room temperature.
  • Auto Zyme Albumin can be used on any Spectrophotometer, Discrete semiautomated and Automated analyzer. Programme can be designed for any specific analyzer upon request.
  • The shelf-life of Auto Zyme Albumin is 18 months.
PRINCIPLE

Serum albumin in the presence of Bromocresol-green under acidic condition forms a green coloured complex. The absorbance of this complex is proportional to the albumin concentration in serum or plasma.

PREPARATION OF WORKING SOLUTION
  • The reagent is ready-to-use.
  • REAGENT STORAGE & STABILITY
  • The reagents are for in vitro diagnostic use.
  • BCG reagent and standard should be stored at temperature indicated on the bottle label.

COMPONENTS & CONCENTRATION OF WORKING SOLUTION

Component

Concentration

 Succinate buffer (pH 3.6)

100 mmol/l

 Bromocresol-green

0.15 mmol/l

Stabilizer

 

SPECIMEN COLLECTION & PRESERVATION

Blood should be collected in a clean dry container. Plastic or siliconized container should be avoided as it may prolong clotting time. Serum is preferred but plasma can also be used. For plasma separation  anticoagulants like EDTA or Heparin can be used. Avoid venous stasis. In absence of bacterial contamination, aloumin is stable in sample for 1 week at room temperature and 1 month at 2-8 degree

 PROCEDURE 

  • Reaction type : End-Point
  • Reaction time :1 Min. at R.T. (25-30 degree C)
  • Wavelength : 600 NM.(600 - 650 nm)
  • ON Zero Setting WITH : REAGENT Blank
  • Blank absorbance limit: 0.100 Abs.
  • Sample Volume :0.01 ml (10 ul)
  • Reagent Volume : 1.0 ml
  • Standard Concentration :5 gm%
  • Linearity : 6 gm

Manual assay procedure

The reagents should be brought to room temperature prior to use.

Perform the assay as given below: 

1.0 ml procedure

 

Serum/Plasma

Standard

Blank

BCG Reagent

0.01 ml

0.01 ml

 

1.0 ml

1.0 ml

1.0 ml

EXECTED VALUES

Adult : 3.5-5.0 gm%

Incubation

Incubate the assay mixture for 1 minute at room temperature(25-30 degree C). After completion of incubation period measure the absorbance against blank at 600 nm. Final colour is stable for ten minutes if not exposed to direct light.

PROCEDURE LIMITATIONS 

  •  If the albumin concentration exceeds 6 gm%, dilute the sample with normal saline and repeat the assay.
  • The test is not influenced by bilirubin values up to 20 mg/dl . Each 100 mg/dl hemoglobin will represent an albumin increase of 0.1 (g/dl.) So gross hemolysis should be avoided.
  • Gross hemolysis and marked lipemia will interfere. A sample blank must be determined by pipetting 101 sample to 1.0 ml normal saline and measured against distilled water. The absorbance of the sample blank has to be subtracted from the absorbance of the sample.

QUALITY CONTROL

To ensure adequate quality control, it is recommended that each batch should include normal and abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting. 