AutoPure Reagents

Product Image (29)

T HDL Cholesterol (Direct) 320

Price: 38770 INR/Kit

Introduction AutoPure T HDL C is a reagent kit for direct quantitative determination of high-density lipoprotein cholesterol (HDL C) in human serum and plasma on automated clinical chemistry analyzers. AutoPure T HDL C is a ready to use, two liquid reagent system. With AutoPure T HDL C, the assay is linear upto 150 mg/dl (3.89 mmol/l Reagent Storage, Stability & Handling AutoPure T HDL-C is a ready to use, two liquid reagent system. Shelf - Life Stable till the expiry date indicated on the label, when stored at 20 - 80C. On - Board Reagent Stability R1 : 60 days at 20 - 80 C after opening. Protect the reagent from light and contamination. R2 : 60 days at 20 - 80 C after opening. Protect the reagent from light and contamination. Do not freeze the reagent

Product Image (30)

T LDL Cholesterol (Direct) 320

Price: 81424 INR/Kit

Introduction AutoPure T LDL C is a reagent kit for direct quantitative determination of low-density lipoprotein cholesterol (LDL-C) in human serum and plasma on automated clinical chemistry analyzers. AutoPure T LDL C is a ready to use, two liquid reagent system. With AutoPure T LDL C, the assay is linear upto 450 mg/dl (11.637 mmo1/1). Reagent Storage, Stability & Handling AutoPure T LDL C is a ready to use, two liquid reagent system. Shelf - Life Stable till the expiry date indicated on the label, when stored at 2 - 8 C.

Product Image (28)

Uric Acid 200

Price: 5402 INR/Kit

Introduction AutoPure Uric Acid is a reagent kit for direct quantitative determination of Uric Acid in human serum and plasma on automated clinical chemistry analyzers. AutoPure Uric Acid is a ready to use, single liquid reagent system. With AutoPure Uric Acid the assay is linear upto 25 mg/dl (1.48,,ol/l). Principle Uricase cleaves uric acid form allantoin and hydrogen peroxide. Uric acid + H2O+ O2 Allantoin + H2O2+ CO2 In presence of peroxidase , hydrogen peroxide oxidatively couples with 4 aminoantipyrine and DHBS to produce red quinoneimine dye. The intensity of the red colour formed is directly proportional to the concentration of the uric acid in the specimen and is measured photometrically. H2O2+4- aminoantipyrine + DHBS -Red quinoneimine dye +H20 DHBS = 3,5 - dichloro-2- hydroxy benzene sulfonic acid

Product Image (27)

Triglycerides 300

Price: 12156 INR/Kit

INTRODUCTION Infinite Liquid Triglycerides is a reagent set for determination of triglycerides, based on enzymatic method using Lipoprotein lipase, Glycerol kinase, Glycerol phosphate oxidase and Peroxidase. Infinite Liquid Triglycerides is a ready - to - use reagent. Triglycerides can be determined in just 10 minutes at 37 degree C or 20 minutes at R.T. (25 degree C - 30 degree C). Infinite Liquid Triglycerides is linear upto 800 mg%. Infinite Liquid Triglycerides can be used on any Colorimeter, Spectrophotometer, Discrete semiautomated and Automated analyzer. Programme can be designed for any specific analyzer upon request. The influence of lipids, haemolysis and bilirubin (upto 8 mg%) is negligible. PRINCIPLE Glycerol released from hydrolysis of triglycerides by lipoprotein lipase is converted by glycerol kinase into glycerol - 3 - phosphate which is oxidised by glycerol phosphate oxidase to dihydroxyacetone phosphate and hydrogen peroxide. In presence of peroxidase, hydrogen peroxide oxidizes phenolic chromogen to a red coloured compound.

Product Image (26)

Total Protein 80

Price: 670 INR/Kit

Introduction AutoPure Total Protein is a reagent kit for direct quantitative determination of total protein in human serum and plasma on automated clinical chemistry analyzers. AutoPure Total Protein is ready to use, single liquid reagent system. With AutoPure Total Protein the assay is linear upto 18 g/dl (180 g/l). Principle Divalent copper ion reacts in alkaline solution with protein peptide bonds to form purple coloured biuret complex. Protein + Cu2+ - Cu - protein complex. The intensity of purple colour formed is directly proportional to the concentration of the total protein in the specimen and is measured photometrically.

Product Image (25)

Phosphorus 80

Price: 1729 INR/Kit

Introduction AutoPure Phosphorus is a reagent kit for direct quantitative determination of phosphorus in human serum and plasma on automated clinical chemistry analyzers. AutoPure Phosphorus is ready to use, single liquid reagent system. With AutoPure Phosphorus, the assay is linear upto 20 mg/dl (6.46 mmo1/1). Principle Inorganic phosphorus reacts with ammonium molybdate at acidic pH to form ammonium - phosphomolybdate complex. Phosphorus + Ammonium molybdate- Ammonium- phospho-molybdate complex The absorbance of this complex formed is directly proportional to the concentration of phosphorus in the specimen and is measured photometrically.

Product Image (24)

Magnesium 80

Price: 3241 INR/Kit

Introduction AutoPure Magnesium is a reagent kit for direct quantitative determination of magnesium in human serum and plasma on automated clinical chemistry analyzers. AutoPure Magnesium is ready to use, single liquid reagent system. With AutoPure Magnesium, the assay is linear upto 5 mg/dl (2.06 mmo1/1). Principle Magnesium ions reacts with xylidyl blue in an alkaline medium to form purple coloured complex. Mg-+ Xylidyl blue - Magnesium-xylidyl blue complex The intensity of the purple colour formed is directly proportional to the concentration of magnesium in the specimen and is measured photometrically. Note: Calcium is excluded from the reaction by complexing with EGTA.

Product Image (23)

Lipase 30

Price: 8509 INR/Kit

Introduction AutoPure Lipase is reagent kit for direct quantitative determination of Lipase in human serum and plasma on automated clinical chemistry analyzers AutoPure Lipase is a ready to use two liquid reagent system With AutoPure Lipase the assay is linear upto 300 IU1 501 p katI Principle The chromogenic Lipase substrate 12 o dilauryl rac glycero 3 glutaric acid6methylresorufin ester is cleaved by the catalytic action of lipase to form 12 o dilauryl rac glycerol and an unstable intermediate glutaric acid 6 methylresorufin ester This decomposes spontaneously in alkaline medium to form glutaric acid and methylresorufin 12 o dilauryl rac glycero 3 glutaric acid 6 methylresorufin easter 1 2 o dilauryl rac glycerol Glutaric acid 6 methylresorufin ester The Lipase activity in specimen is directly proportional to the rate of formation of methylresorufin in the reaction and can be determined kinetically

Product Image (21)

LDL Cholesterol 240

Price: 61068 INR/Kit

Introduction AutoPure HDL C is a reagent kit for direct quantitative determination of HDL-C in human serum and plasma on automated clinical chemistry analyzers. AutoPure HDL C is ready to use, two liquid reagent system. With AutoPure HDL C, the assay is linear upto 150 mg/dl (3.89 mmo1/1). Reagent Storage, Stability & Handling AutoPure HDL C is ready to use, two liquid reagent system. Shelf life Stable till the expiry date indicated on the label, when stored at 2 -8 C.

Product Image (20)

HDL Cholesterol 240

Price: 29078 INR/Kit

Introduction AutoPure HDL C is a reagent kit for direct quantitative determination of HDL C in human serum and plasma on automated clinical chemistry analyzers. AutoPure HDL C is ready to use two liquid reagent system. With AutoPure HDL C, the assay is linear upto 150 mg/dl (3.89 mmo1/1). Reagent Storage, Stability & Handling AutoPure HDL C is ready to use, two liquid reagent system Shelf life Stable till the expiry date indicated on the label, when stored at 2 -8 C. On - Board Reagent Stability R1: 60 days at 2 - 8 C after opening R2 : 60 days at 2 - 8 C after opening . Protect the reagent from light and contamination. Do not freeze the reagent.

Product Image (19)

Homocysteine 25

Price: 43713 INR/Kit

Introduction AutoPure Homocysteine is a reagent kit for quantitative determination of L homocysteine in human serum and plasma on automated clinical chemistry analyzers. AutoPure Homocysteine is a ready to use, two liquid reagent system. With AutoPure Homocysteine, the assay is linear up to 50 pmo1/1. Principle AutoPure Homocysteine assay is based on the measurement of co substrate conversion product. Oxidized Homocysteine from the sample is reduced to free Homocysteine which then reacts with SAM to form methionine and SAH. SAH is assessed by coupled enzyme reactions where in adenosine is formed. The adenosine formed is hydrolyzed into inosine and ammonia which reacts with glutamate dehydrogenase with concomitant conversions of NADH to NAD*. The concentration of Homocysteine is proportional to the amount of NADH converted to NAD+ and is measured as change in absorbance at 340 nm.

Product Image (18)

GPT (AST) 220

Price: 5349 INR/Kit
  • Type:Industrial Lab Chemicals
  • Purity(%):99%
  • Grade:Industrial
  • Delivery Time:2 Days
  • Supply Ability:10000 Per Day
Product Image (17)

GOT (AST) 220

Price: 5349 INR/Kit

Introduction AutoPure AST GOT is a reagent kit for direct quantitative determination of aspartate transaminase AST in human serum and plasma on automated clinical chemistry analyzers AutoPure AST GOT is a ready to use two liquid reagent system With AutoPure AST GOT the assay is linear upto 800 IUI 1336 ukatI Principle ketoglutarate reacts with L aspartate in the presence of AST GOT to form oxaloacetate and L glutamate ketoglutarate Laspartate oxaloacetate L glutamate The increase in oxaloacetate is determined in an indicator reaction catalyzed by malate dehydrogenas oxaloacetate NADH H Lmalate NAD The conversion of NADH to NAD is proportional to the AST GOT activity in the specimen and is determined kinetically

Product Image (16)

Glucose Hexokinase 200

Price: 3987 INR/Kit

Introduction Autopure Glucose Hexokinase is a reagent kit for quantitative determination of Glucose concentration in human serum or plasma based on Hexokinase method Autopure Glucose Hexokinase is a ready to use two liquid reagent system With Autopure Glucose Hexokinase the assay is linear upto 600 mgdL Clinical Significance Estimation of glucose concentration is important in the diagnosis and management of hyperglycaemia and hypoglycaemia Condition of Hyperglycaemia may occur as a result of diabetes mellitus patients intravenously receiving glucose containing fluids during severe stress and cerebrovascular accidents Hypoglycaemia may be the result of an insulinoma insulin administration inborn errors of carbohydrate metabolism or fasting

Product Image (15)

Glucose 300

Price: 1621 INR/Kit

Introduction AutoPure Glucose is a reagent kit for direct quantitative determination of glucose in human serum and plasma on automated clinical chemistry analyzers. AutoPure Glucose is a single ready to use reagent. With AutoPure Glucose, the assay is linear upto 500 mg/dl (27.75 mmo1/1). Principle Glucose oxidase, oxidizes glucose to gluconic acid in the presence of atmospheric oxygen. 13- D glucose + 02+ H2O - Gluconic acid + H202 In presence of peroxidase, hydrogen peroxide oxidatively couples with 4 - aminoantipyrine and phenol to produce red quinoneimine dye. The intensity of the red colour formed is directly proportional to the concentration of glucose in the specimen and is measured photometrically. H202+ 4 - aminoantipyrine + phenol - Red quinoneimine dye + H20

Product Image (14)

Gamma-GT 60

Price: 5673 INR/Kit

Introduction AutoPure Gamma- GT is a reagent kit for direct gamma - glutamyltransferase ( GGT ) in human serum and plasma on automated clinical chemistry analyzers. AutoPure Gamma- GT is ready to use , two liquid reagent system. With AutoPureGamma- GT the assay is linear upto 1200 IU/I( 20.04 ukat/l)). Reagent Storage, Stability & Handling AutoPureGamma- GT is a ready to use two liquid reagent system. Shelf life Stable till the expiry date indicated on the label, when stored at 2- 8 C.

Product Image (13)

Creatinine Enzymatic 120

Price: 5991 INR/Kit

Introduction Autopure Creatinine (Enzymatic) is a reagent kit for quantitative determination of creatinine concentration in human serum and urine based on enzymatic method. Autopure Creatinine (Enzymatic) is a ready to use, two liquid reagent system. With Autopure Creatinine (Enzymatic), the assay is linear upto 200 mg/dL. Clinical Significance Creatinine is a chemical waste molecule that is generated from muscle metabolism. Creatinine is produced from creatine, a molecule of major importance for energy production in muscles. Approximately 2% of the bodys creatine is converted to creatinine every day. Creatinine is transported through the bloodstream to the kidneys. The kidneys filter out most of the creatinine and dispose it of in the urine. The kidneys maintain the blood creatinine in a normal range. Creatinine has been found to be a fairly reliable indicator of kidney function. As the kidneys become impaired the creatinine level in the blood will rise. Abnormally high levels of creatinine thus warn of possible malfunction or failure of the kidneys.

Product Image (12)

Cholesterol 300

Price: 7293 INR/Kit

Infinite Liquid Cholesterol is a reagent set for determination of total cholesterol based on enzymatic method using Cholesterol esterase, Cholesterol oxidase and Peroxidase. Infinite Liquid Cholesterol is a ready -to-use reagent. Infinite Cholesterol can be determined in just 5 minutes at 37 Degree C or 10 minutes at R.T. (25 -30 Degree C). Infinite Liquid Cholesterol is linear upto 1000 mg%. Infinite Liquid Cholesterol can be used on any Colorimeter Spectrophotometer, Discrete semiautomated and Automated analyzer. Programme can be designed for any specific analyzer upon request. The influence of Ascorbic acid, Bilirubin, Haemoglobin, Glucose, Sodium fluoride, Heparin, EDTA, Creatinine and Uric acid is negligible. Infinite Liquid Cholesterol reagent system can also be used for determining HDL Cholesterol. The HDL ppt reagent and standard can be ordered separately. PRINCIPLE Cholesterol esterase hydrolyses cholesterol esters into free cholesterol and fatty acids. In the second reaction cholesterol oxidase converts cholesterol to cholest-4-en-3-one and hydrogen peroxide. In presence of peroxidase, hydrogen peroxide oxidatively couples with 4 - aminoantipyrine and phenol to produce red quinoneimine dye which has absorbance maximum at 510 nm. (500 - 530). The intensity of the red colour is proportional to the amount of total cholesterol in the specimen.

Product Image (11)

Chloride 80

Price: 2403 INR/Kit

Introduction AutoPure Chloride is a reagent kit for direct quantitative determination of Chloride in human serum and plasma on automated clinical chemistry analyzers. AutoPure Chloride is ready to use , single liquid reagent system. With AutoPure Chloride, the assay is linear upto 130 mg/dl( 458.9 mmol/l). Principle Chloride ions react with mercuric thiocyanate to form undissociated mercuric chloride and free thiocyanate ions. Hg (SCN)2 + 2 Cl- hgcl2 + 2SCN Thiocyanate ions react with trivalent ferric ions present in the solution to form a red coloured complex of ferric thiocyanate. 3 (SCN)+ Fe3 - Fe( SCN) 3 The intensity of the red colour formed is directly proportional to the concentration of chloride in the specimen and is masured photometrically .

Product Image (10)

CK MB 25

Price: 8600 INR/Kit

INTRODUCTION Infinite Liquid CK - MB is a reagent set for determination of CK - MB activity in serum and plasma based on immunoinhibition method. Infinite Liquid CK - MB is a ready-to-use, two liquid reagent system. Infinite Liquid CK - MB estimates CK - MB activity in just 6/ minutes. Infinite Liquid CK - MB is linear upto 2000 IU/I. Infinite Liquid CK - MB can be used on any Spectrophotometer, Discrete semiautomated and Automated analyzers. Programme can be designed for any specific analyzer upon request. Infinite Liquid CK - MB is stable till expiry at 2 - 8 Degree C. PRINCIPLE The serum sample is incubated with CK - MB reagent containing antibody specific to CK-M subunit which completely inhibits the CK-M monomer. The activity of CK-B which is not inhibited by the antibody, is then measured by the following reaction sequence:

Product Image (09)

Ck Nac 25

Price: 4500 INR/Kit

Introduction AutoPure CK-NAC is a reagent kit for direct quantitative determination of CK-NAC in human serum and plasma on automated clinical chemistry analyzers. AutoPure CK-NAC is ready to use , two liquid reagent system. With AutoPure CK-NAC, the assay is linear upto 2000 IU/I( 33.4 ukat/l)). Principle Creatine kinase catalyzes the conversion of creatine phoosphate and ADP to creatine and ATP. Creatine phosphate + ADP- creatine + ATP ATP phosphorylates glucose to glucose - 6 - phosphate in presence of hexokinase. ATP + Glucose - Glucose- 6- phosphate + ADP Glucose-6-phosphate is oxidised to 6 - phosphogluconate, reducing NADP to NADPH in presence of Glucose-6-phosphate dehydrogenase. Glucose-6- phosphate + NADP- 6-phosphogluconate + NADPH+ H The rate of increase in absorbance due to intensity of the NADPH form action is directly proportional to the concentration of creatine kinase activity in the specimen and is measured kinetically.

Product Image (08)

Calcium Arsenazo III 80

Price: 1838 INR/Kit

Introduction AutoPure Calcium Arsenazo III is a reagent kit for direct quantitative determination of calcium in human serum and plasma on automated clinical chemistry analyzers. AutoPure Calcium Arsenazo III is ready to use, single liquid reagent system. With AutoPure Calcium Arsenazo III, the assay is linear upto 15 mg/dl (3.75 mmo1/1). Principle Arsenazo III reacts with calcium ions at neutral pH to form a blue coloured complex. Ca + +Arsenazo III - Calcium - arsenazo complex The intensity of the blue colour formed is directly proportional to the concentration of calcium in the specimen and is measured photometrically.

Product Image (07)

Bun Urea 240B

Price: 5835 INR/Kit

Introduction AutoPure Urea/BUN is a reagent kit for direct quantitative determination of Urea/BUN in human serum and plasma on automated clinical chemistry analyzers. AutoPure Urea/BUN is ready to use ,two liquid reagent system. With AutoPure Urea/BUN , the assay is linear upto urea 535 mg/dl (88.8 mmol/l) urea nitrogen 250 mg/dl(41.5 mmol/l) Principle Urea hydrolysed by urease to form ammonia and carbon dioxide. Urea + h2o- NH2+ CO2 The ammonia formed then reacts with a- ketoglularate and NADH in presence of glutarmate dehydrogenase to yield glutamate and NAD NH3+ a- Ketoglutarate+ NADH-L- glutamate + NAD The decrease in absorbance due to NADH consumption is directly proportional to the urea/urea nitrogen concentration in the specimen and is measured kinetically.

Product Image (22)

LDH 48

Price: 3241 INR/Kit

Introduction AutoPure LDH is reagent kit for direct quantitative determination of Lactate Dehydrogenase (LDH) in human serum and plasma on automated clinical chemistry analyzers. AutoPure LDH is a ready to use, two liquid reagent system. With AutoPure LDH, the assay is linear upto 1200 IU/1 (20.04 pkat/I). Principle Lactate dehydrogenase catalyzes the conversion of pyruvate to lactate. Pyruvate + NADH +1-14- Lactate + NAD The conversion of the NADH to NAL). is directly proportional to the LDH activity in the specimen and is measured kinetically.

Product Image (06)

Bilirubin Total 164

Price: 3355 INR/Kit

Introduction AutoPure Bilirubin is a reagent kit for direct quantitative determination of total and direct bilirubin in human serum and plasma on automated clinical chemistry analyzers. AutoPure Bilirubin is ready to use ,two liquid reagent system. With AutoPure Bilirubin , the assay is linear upto 20 mg/dl( 342mmol/l). Principle Bilirubin reacts with diazotized sulphanillic acid in acidic medium to produce azobillirubin . DMSO catalyzes the formation of azobillirubin from free bilirubin. Bilirubin+ Sulphanilic acid + Sodiu Nitrite- Azobilirubin Direct Bilirubin, being water soluble directly reacts in acidic medium to produce Azobilirubin . Bilirubin+ Sulphanilic acid + Sodiu Nitrite- Azobilirubin The intensity of the violet colour formed is directly proportional to the concentration of bilirubin in the specimen and is measured photometrically. Abbreviations: DMSO= Dimethyl Sulphoxide

Product Image (05)

Bilirubin Direct 164

Price: 3355 INR/Kit

Introduction AutoPure Bilirubin is a reagent kit for direct quantitative determination of total and direct bilirubin in human serum and plasma on automated clinical chemistry analyzers. AutoPure Bilirubin is ready to use ,two liquid reagent system. With AutoPure Bilirubin , the assay is linear upto 20 mg/dl( 342mmol/l). Principle Bilirubin reacts with diazotized sulphanillic acid in acidic medium to produce azobillirubin . DMSO catalyzes the formation of azobillirubin from free bilirubin. Bilirubin+ Sulphanilic acid + Sodiu Nitrite- Azobilirubin Direct Bilirubin, being water soluble directly reacts in acidic medium to produce Azobilirubin . Bilirubin+ Sulphanilic acid + Sodiu Nitrite- Azobilirubin The intensity of the violet colour formed is directly proportional to the concentration of bilirubin in the specimen and is measured photometrically. Abbreviations: DMSO= Dimethyl Sulphoxide

Product Image (04)

ADA 33

Price: 9026 INR/Kit

ADA IS A SENSITIVE AND SPECIFIC MARKER ADA is widely distributed in human tissues, with the highest activities found in T-Lymphocytes, monocytes and macrophages Its main physiological activity is related to lymphocytic proliferation and differentiation ADA has great clinical utility as a marker for cellular immunity and cell-mediated hypersensitive reactions. ANALYTICAL ADVANTAGES Accurex ADA assay kit has significant advantages over the older Giusti and Galanti method. fully liquid stable formulation Can be run either manually or on open automated chemistry system

Product Image (03)

Amylase 40

Price: 8104 INR/Kit

Introduction AutoPure a-Amylase is a reagent kit for direct quantitative determination of a-Amylase in human serum and plasma on automated clinical chemistry analyzers. AutoPure a-Amylase is a ready to use, single liquid reagent system. With AutoPure a-Amylase the assay is linear upto 2000 IU/I(33.4 ukat/l). Principle a-Amylase involves use of a chromogenic substrate Gal,G2-a CNP(2 - chloro- 4- nitrophenyl linked with galactosylmaltoside.). The direct action of a-Amylase with this substrate results in the release of more than 90% of 2 - chloro- 4 nitrophenol. Gal-G2-a-CNP- 2- chloro-4 - nitrophenal+ Gal-G2 The intensity of the 2 - chloro-4 nitrophenol formed is directly proportional to the a-Amylase activity in the specimen and is measured photometrically.

Product Image (02)

Alkaline Phosphatase 100

Price: 2702 INR/Kit

brand name : ACCUREX BIOMEDICAL

Product Image (01)

Albumin 200

Price: 1675 INR/Kit

Introduction AutoPure Albumin is a reagent kit for direct quantitative determination of albumin in human serum and plasma on automated clinical chemistry analyzers AutoPure Albumin is a ready to use single liquid reagent system With AutoPure Albumin the assay is linear upto 6 gdl 60 gl Principle Serum albumin binds with the indicator bromocresol green BCG under acidic conditions to form a green coloured complex albumin BCG albumin BCG complex The intensity of the green colour formed is directly proportional to the concentration of albumin in the specimen and is measured photometrically

X


Back to top
ACCUREX BIOMEDICAL PVT. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.