Bun Urea 240B

Bun Urea 240B

Product Details:

  • Appearance Biochemistry Reagent
  • Shape other
  • Other Names Biochemistry Reagent
  • Usage AutoPure Urea/BUN is ready to use ,two liquid reagent system. With AutoPure Urea/BUN , the assay is linear upto urea 535 mg/dl (88.8 mmol/l) urea nitrogen 250 mg/dl(41.5 mmol/l)
  • Taste Other
  • Shelf Life 18 Months
  • Smell Other
  • Supply Ability : 10000 Kit Per Day
5835 INR/Kit
X

Price And Quantity

  • 1 Kit
  • 5835 INR/Kit

Product Specifications

  • 18 Months
  • Biochemistry Reagent
  • Other
  • Liquid
  • Other
  • Other
  • Reagents
  • AutoPure Urea/BUN is ready to use ,two liquid reagent system. With AutoPure Urea/BUN , the assay is linear upto urea 535 mg/dl (88.8 mmol/l) urea nitrogen 250 mg/dl(41.5 mmol/l)
  • ACC9055
  • Biochemistry Reagent
  • Biochemistry Reagent
  • 100
  • other

Trade Information

  • EXW ABPL
  • Paypal, Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Letter of Credit (L/C), Letter of Credit at Sight (Sight L/C)
  • 10000 Kit Per Day
  • 2 Days
  • Yes
  • packaging : Empity
  • Asia, North America, South America, Middle East, Africa
  • All India
  • certification : iso

Product Description

Introduction

  •  AutoPure Urea/BUN  is a reagent kit for direct quantitative determination of  Urea/BUN in human serum and plasma on automated clinical chemistry analyzers.
  •   AutoPure  Urea/BUN is ready to use ,two liquid reagent system.
  • With   AutoPure Urea/BUN , the assay is linear upto  urea 535 mg/dl (88.8 mmol/l) urea nitrogen 250 mg/dl(41.5 mmol/l)

Principle 

  • Urea hydrolysed by urease to form ammonia and carbon dioxide. 
  • Urea + h2o- NH2+ CO2
  • The ammonia formed then reacts with a- ketoglularate and NADH in presence of glutarmate dehydrogenase to yield glutamate and NAD
  • NH3+ a- Ketoglutarate+ NADH-L- glutamate + NAD 
  • The decrease in absorbance due to NADH consumption is directly proportional to the urea/urea nitrogen concentration in the specimen and is measured kinetically.

Reagent Storage, Stability & Handling

AutoPure  Urea/BUN is a ready to use two liquid reagent system. 

Shelf life  

Stable till the expiry date indicated on the label, when stored at 2- 8 C.

On Board Reagent Stability

  • R1:30 days at 2-8 C after opening.
  • R2: 30 days at 2-8 C after opening.
  • Protect the reagent from light and contamination .
  • Do not freeze the reagent.

Components & Concentration of Working Solution 

 Components                                                                                     Concentration 

R1

  • Tris buffer : ph9.5                                                                      15mmol/l
  • NADH                                                                                        >0.25 mmol/l
  • Stabilizers, excipients & surface active agents. 

R2

  • Tris buffer:ph 7.5                                                                                   320mmol/l
  • Urease                                                                                                     >11,000IU/I
  • GLDH, ADP free                                                                                       > 700IU/I
  • a-ketoglutarate                                                                                             > 10 mmol/l
  • Stabilizers, excipients & surface active agents 

Specimen collection & Preservation

Collect sample using standard sampling tube. Although serum is preferred, heparinized plasma or EDTA plasma can be used . Anticogulants such as ammonium heparin and floride should not be used. Uura/BUN  in serum/plasma is stable for 6 days at 2- 8 C and 6 month at - 20 C. Centrifuge samples containing precipitate before performing assay . 

Calculations 

Fully automated system automatically calculated the Uura/BUN  concentration of each samples.

  •  Result in mmol/l ( urea )= Result in mg/dl (urea) x0.166
  •   Result in mmol/l ( urea )= Result in mg/dl (urea) x 6.024
  •  Result in mmol/l ( urea )= Result in mg/dl (urea nitrogen ) x 2.14 
  •  Result in mmol/l ( urea )= Result in mg/dl (urea nitrogen ) x 0.357
  •  Result in mmol/l ( urea  nitrogen )= Result in mg/dl (urea) x 0.467

Application Sheet 

Refer to the application sheet for details. For additional system applications, contact our local accurex representative.

Calibration

 For calibration , it is recommended to use C.F a.s or any other suitable calibrator material.

Calibration frequency  

Re- calibration is recommended 

  • Whenever the reagent lot is changed .
  • As per the requirement of quality control procedured.

Quality Control

Each batch of autopure bilirubin is assayed with atleast six quality control sera- Precinorm, precipath, bioradl, bioradll, accutrol normal and Accutrol abnormal prior to release.

To ensure adequate quality control, it is recommended that the laboratory should use a normal and abnormal commerical reference control serum. It should be realized that the use of quality control material checks both the reagent and instrument functions together.

If the control values fall outside the specified limits, each of the below criteria should be cross checked and corrected:

  • Proper instruments function- wavelength setting, light source and temperature control.
  • Cleanliness of probes and cuvettes.
  • Bacterial contamination of wash water used by the instrument.
  • Expiry date of the reagent kit. 

Expected Values 

Serum/Plasma

  • Urea:10 - 45 mg/dl (1.7-7.5mmol/l)
  • Urea nitrogen (BUN) : 5- 21 mg/dl ( 0.84- 3.5 mmol/l)

Note: 

Expected range varies from population to population. it is therefore recommended that each laboratory should establish its own normal range. For diagnostic purposes, the bilirubin results should always be assessed in diagnostic purposes, the bilirubin results should always be assessed in conjuction with the patients medical history clinical examinations and other findings.

Performance Characteristics 

Linearity 

With Autopure Urea/BUN , the assay is linear up to urea 535 mg/dl (88.8mmol/l) urea nitrogen 250 mg/dl(41.5 mmol/l) .Determine samples with higher concentration via the rerun function . On instrument without rerun function, manually dilute samples with higher concentration using 0.9% NaCl or distilled/deionized water (e.g. 1+2 ). Multiply the result by the appropriate dilution factor (e.g. 3).

Interference 

There is no significant interference in samples containing upto 60 mg/dl of bilirubin and 700 mg/dl of haemoglobin.

Ammonia produced in the cuvette during a GLDH determination interferes with the urea/urea nitrogen assay. The AutoPure Urea/BUN reagent must therefore not be installed on the analyzers together with reagents for the GLDH test. Great care must be taken to prevent ammonia contamination of the specimen and calibrator used in the urea/urea nitrogen assay.

Precision

Reproducibility was determined using quality control sera as shown below

Within run

Between run

 

Quality control material

Means mg/dl

sd mg/dl

CV

Means mg/dl

sd mg/dl

CV

low control serum

43

0.50

2.5

39

0.50

2.8

high control serum

158

0.60

0.8

150

2.00

2.3

Co- Relation Studies

A comparison of the bilirubin determination using autopure bilirubin and reference competitors bilirubin reagent gave the following co- realtion (mg/dl):

Linear Regression

  • y=                             0.984x +0.1962 
  • r=                             0.9726
  • Sy.x=                      0.41

No of samples measured :78

The samples concentrations measured were between 13.5 and 28.9 mg/dl.