Control & Calibrators Reagents

Product Image (12)

Control for CBC 360 Neo

Price: 6045 INR/Kit

brand name : ACCUREX BIOMEDICAL

Product Image (11)

AutoPure Homocysteine Control Low And High

Price: 6300 INR/Kit

Introduction Homocysteine Control Low & High are intended to be used for quality control check during the determination of Homocysteine using Auto Pure Homocysteine kit. Control Storage, Stability & Handling Shelf - life & Stability Homocysteine Controls are stable until the expiration date printed on the vial label when stored at 2 - 8 degree C. Preparation of Control Homocysteine Controls are liquid, ready-to-use. DO NOT FREEZE.

Product Image (10)

AutoPure Homocysteine 5 Level Calibrator

Price: 6300 INR/Kit

Introduction Homocysteine 5 level calibrator is intended to be used for the calibration of Homocysteine assay. Calibrator Storage, Stability & Handling Shelf - Life Unopened calibrators are stable when stored at 2 - 80C until the expiration date printed on the vial label. Preparation of Calibrator & Stability Homocysteine Calibrators are liquid, ready to use.DO NOT FREEZE. Calibrator Concentration Concentration of each calibrator is printed on the vial label. Indications of Deterioration Presence of extreme turbidity or microbial growth may indicate deterioration.

Product Image (09)

Autopure HbA1c Control Low And High 1

Price: 6800.00 INR/Kit

Introduction HbA1c 4 level calibrator is intended to be used for the calibration of H bA1 c assay. Calibrator Storage, Stability & Handling Shelf- Life Unopened calibrators are stable when stored at 2 degree - 8 degree C until the expiration date printed on the vial label. Preparation of Calibrator & Stability Each lyophilized HbA1c calibrator should be reconstituted by adding 0.5 ml of distilled or deionized water. Close the vial and dissolve the contents by swirling gently to avoid formation of foam. Do not shake. Allow it to stand for 20 minutes before use. Reconstituted HbA1c calibrators are stable for 30 days at 2 degree - 8 degree C. DO NOT FREEZE.

Product Image (07)

Autopure - T-LDL Cholestrol-Calibrator

Price: 61068 INR/Kit

Introduction T-LDL Calibrator is intended to be used for the calibration of HDL-C assay. Calibrator Storage, Stability & Handling Shelf - Life Unopened calibrator is stable when stored at 2 - 8 degree C until the expiration date printed on the vial label. Preparation of Calibrator & Stability Lyophilized serum T-LDL Calibrator should be reconstituted by adding 1.0 ml of distilled or deionized water. Close the vial and let stand for 20 minutes. Dissolve the contents of the vial by swirling gently to avoid the formation of foam. Do not shake. Reconstituted T-LDL Calibrator is stable for 14 days at 2 -8 degree C. Reconstitution stability of the calibrator may be extended upto 28 days by aliquoting and freezing the reconstituted calibrator preparation at less than -80 degree C.

Product Image (05)

Cystatine C control low And High

Price: 1367 INR/Kit

brand name : ACCUREX BIOMEDICAL

Product Image (04)

ADA Control Low High

Price: 12156 INR/Kit

INTRODUCTION Infinite ADA is a reagent set for direct quantitative determination of Adenosine deaminase (ADA) activity in human serum, plasma and other body fluids. Infinite ADA is a ready-to-use, two liquid reagent system. With Infinite ADA, the assay is linear upto 200 U/L. Infinite ADA assay can be performed in 11 minutes at 37 C. PRINCIPLE ADA catalyses deamination of adenosine to inosine which is then converted to hypoxanthine by purine nucleosidephosphorylase (PNP). Hypoxanthine is then converted to uric acid and hydrogen peroxide (H2O2) by xanthine oxidase (XOD). H2O2 is further reacted with N-Ethyl-N-(2-hydroxy-3-sulfopropyl)-3-methylaniline (EHSPT) and 4-aminoantipyrine (4 AAP) in the presence of peroxidase (POD) to generate quinone dye. denosine + H2O Inosine + NH3 PNP Inosine + Pi Hypoxanthine + Ribose-1-phosphate XOD Hypoxanthine + 2H2O + 2O2 Uric acid + 2 H2O2 POD 2 H2O2 + 4AAP + EHSPT 4 H2O + Quinone dye The intensity of the colour developed is directly proportional to the activity of ADA in the specimen and is measured kinetically.

Product Image (03)

ADA Calibrator

Price: 5943 INR/Kit

INTRODUCTION Infinite ADA is a reagent set for direct quantitative determination of Adenosine deaminase (ADA) activity in human serum, plasma and other body fluids. Infinite ADA is a ready-to-use, two liquid reagent system. With Infinite ADA, the assay is linear upto 200 U/L. Infinite ADA assay can be performed in 11 minutes at 37 C. PRINCIPLE ADA catalyses deamination of adenosine to inosine which is then converted to hypoxanthine by purine nucleosidephosphorylase (PNP). Hypoxanthine is then converted to uric acid and hydrogen peroxide (H2O2) by xanthine oxidase (XOD). H2O2 is further reacted with N-Ethyl-N-(2-hydroxy-3-sulfopropyl)-3-methylaniline (EHSPT) and 4-aminoantipyrine (4 AAP) in the presence of peroxidase (POD) to generate quinone dye. denosine + H2O Inosine + NH3 PNP Inosine + Pi Hypoxanthine + Ribose-1-phosphate XOD Hypoxanthine + 2H2O + 2O2 Uric acid + 2 H2O2 POD 2 H2O2 + 4AAP + EHSPT 4 H2O + Quinone dye The intensity of the colour developed is directly proportional to the activity of ADA in the specimen and is measured kinetically.

Product Image (08)

HbA1c 4 Level Calibrator

Price: 9126 INR/Kit

Introduction HbA1c 4 level calibrator is intended to be used for the calibration of H bA1 c assay. Calibrator Storage, Stability & Handling Shelf- Life Unopened calibrators are stable when stored at 2 degree - 8 degree C until the expiration date printed on the vial label. Preparation of Calibrator & Stability Each lyophilized HbA1c calibrator should be reconstituted by adding 0.5 ml of distilled or deionized water. Close the vial and dissolve the contents by swirling gently to avoid formation of foam. Do not shake. Allow it to stand for 20 minutes before use. Reconstituted HbA1c calibrators are stable for 30 days at 2 degree - 8 degree C. DO NOT FREEZE.

Product Image (06)

Autopure T HDL Cholestrol Calibrator

Price: 3925 INR/Kit

Introduction T HDL-C Calibrator is intended to be used for the calibration of HDL-C assay. Calibrator Storage, Stability & Handling Shelf - Life Unopened calibrator is stable when stored at 2 - 8 degree C until the expiration date printed on the vial label. Preparation of Calibrator & Stability Lyophilized serum T HDL-C Calibrator should be reconstituted by adding 1.0 ml of distilled or deionized water. Close the vial and let stand for 20 minutes. Dissolve the contents of the vial by swirling gently to avoid the formation of foam. Do not shake. Reconstituted T HDL-C Calibrator is stable for 14 days at 2 -8 degree C. Reconstitution stability of the calibrator may be extended upto 28 days by aliquoting and freezing the reconstituted calibrator preparation at less than -80 degree C.

Product Image (02)

Accutrol Biochemistry Control (2x5) ml

Price: 2252 INR/Kit

brand name : ACCUREX BIOMEDICAL

X


Back to top
ACCUREX BIOMEDICAL PVT. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.